136
Step 3: ETM® System Configuration
c.
In the
Remote Point Code
box, type the point code (RPC) of
the remote switch or the CO/IEC switch to which the Bearer trunks
are connected.
d.
In the
Glare Control
box, click the down arrow, and then click
the value used by the local switch. The available values are
None
,
All
, or
Even/Odd
.
e.
In the
Associated Signaling Links
box, click
Edit
. The
Associated SS7 Signaling Links
dialog box appears.
1)
In the
Exclude
box, double-click the Signaling Link(s)
associated with the Bearer Spans in this SS7 Group, or
click it and then click the right-facing arrow. The
Signaling Link(s) move to the
Include
box.
2)
Click
OK
.
The Signaling Link(s) appear in the
Associated SS7 Signaling
Links
box of the
SS7 Group Properties
dialog box.
f.
Click
OK
.
14.
In the
Telco Configuration
subtree, hold down CTRL, click each
SS7 Bearer Span that is to be a member of the SS7 Group, right-click
the selection, point to
Move Span(s)
, and then click
To SS7 Group
.
The
Move Span(s) to SS7 Group
dialog box appears.