5 Introduction of operation and running SV800/SV800A User Manual
58
No.
Contents
Remarks
□
12
Whether the motor self-learning completed?
□
13
Whether the settings of the protection parameters
correct?
□
14
Does the carrier frequency of the inverter need to be
modify? Whether the motor need to run at a state
with low speed and large torque?
No.
Contents
Remarks
Close-loop vector control mode check
□
15
Whether the settings of the speed sensor parameters
correct?
□
16
Whether running direction of the motor match to
the sequence of the speed sensor signal wiring?
□
17
Whether the running direction and speed interval of
the motor correct?
□
18
Whether the motor self-learning completed?
□
19
Whether the setting of the protection parameters
correct?
□
20
Does the carrier frequency of the inverter need to be
modify? Whether the motor need to run at a state
with low speed and large torque?
V/F control mode check
□
21
Whether the parameters setting of motor nameplate
correct?
□
22
Whether the cable length between the motor and the
frequency inverter more than 50M? Is it necessary
to perform self-learning?
□
23
Does the carrier frequency of the inverter need to be
modify? Whether it needs large torque when start
up the motor?