![SCOV SV800 Series User Manual Download Page 126](http://html.mh-extra.com/html/scov/sv800-series/sv800-series_user-manual_1219567126.webp)
6 Function Parameters List SV800/SV800A User Manual
118
F3:Lift and hoist equipment parameters
No.
Name
Content
Set value
F3-00
(5300H)
Lift and hoist equipment
function Enable
ALL
0: Invalid
1: Valid
Factory default
:
0
Range
:
0~1
F3-01
(5301H)
Release brake torque
threshold
ALL
Factory default
:
100%
Range
:
0%~300%
F3-02
(5302H)
Release brake delay time
ALL
Factory default
:
3.0s
Range
:
0.0s~3600.0s
F3-03
(5303H)
Brake frequency value
ALL
Factory default
:
3.00Hz
Range
:
0.00Hz~50.00Hz
F3-04
(5304H)
Brake delay time
ALL
Factory default
:
3.0s
Range
:
0.0s~3600.0s
F3-05
(5305H)
Emergency brake Enable
ALL
0: Invalid
1: Valid
Factory default
:
0
Range
:
0~1
F3-06
(5306H)
Release brake frequency
value
ALL
Factory default
:
3.00Hz
Range
:
0.00Hz~50.00Hz
F3-07
(5307H)
Release brake time
ALL
Factory default
:
3.0s
Range
:
0.0s~10.0s