2 Product Introduction SV800/SV800A User Manual
10
Code
Rated load
Heavy load
High heavy
load
Carrier frequency
range
Model name
I
N
A
I
Max
A
P
N
kW
I
Hd
A
P
Hd
kW
I
HH
A
P
HH
kW
Min
kHz
Max
kHz
2804
510
765
280
415
220
350
185
1.0
15.0
SV800-2804G/3154P
3154
600
900
315
460
250
370
200
1.0
15.0
SV800-3154G/3554P
3554
660
990
355
510
280
460
250
1.0
15.0
SV800-3554G/4004P
4004
740
1110
400
600
315
460
250
1.0
15.0
SV800-4004G/4504P
4504
820
1230
450
660
355
600
315
1.0
15.0
SV800-4504G/5004P
5004
920
1380
500
740
400
660
355
1.0
15.0
SV800-5004G/5604P
5604
990
1485
560
820
450
740
400
1.0
15.0
SV800-5604G/6304P
6304
1160
1665
600
920
500
740
400
1.0
15.0
SV800-6304G
7504
1380
2070
750
1160
630
920
500
1.0
15.0
SV800-7504G
10004
1840
2760
1000
1380
750
1160
630
1.0
15.0
SV800-10004G
Note: <1>Under vector control, the frequency inverter can drive motors with the power are three to four
times smaller than the inverter power. Standard V/F control does not have this limitation.
<2> The carrier frequency range means that the control algorithm can operate stably under the maximum
carrier frequency, but the motor needs to be de-rated when the carrier frequency is larger than the factory
default value.
2.1.5 Heavy load application and de-rating use of frequency inverter
For rated load application:
The motor is allowed to output a maximum of 1.5 times of the rated torque; I
N
in Table 2-1 is
the rated current that can be used continuously when the inverter is not overloaded; P
N
is the
typical motor power adapted when there is no overload; I
Max
is the maximum overload current
allowed by the inverter, allowing continuous operation for 1 minute / 5 minutes at 40
℃
.
For heavy load application:
The inverter should be derating used by one grade and the motor is allowed to output more than
1.5 times of the rated torque; I
Hd
in Table 2-1 is the rated current of the continuously running
motor. The motor overload protection is set by P0-03 (motor overload protection setting) and
P0-04
~
P0-06 (motor over-torque protection); The output current of the inverter is limited by
I
Max
and allowed to run continuously for 1 minute / 5 minutes at 40
℃
; P
Hd
is the typical motor
power adapted for heavy load applications.
For high heavy load applications:
The inverter should be de-rating used by two grades and the motor allows output greater than
twice times of the rated torque; In table 2-1, I
HH
is the rated current of the continuously running
motor. The motor overload protection is set by P0-03 (motor overload protection setting) and