![SCOV SV800 Series User Manual Download Page 188](http://html.mh-extra.com/html/scov/sv800-series/sv800-series_user-manual_1219567188.webp)
7 Detailed function description SV800/SV800A User Manual
180
7.5.3 F2:Paper towel equipment parameters
No.
Name
Set range
Factory default
F2-00
Enable Non-standard
0
~
1
0
F2-01
Filter coefficient
0.300
~
2.000
0.300
7.5.4 F3:Lift and hoist equipment parameters
No.
Name
Set range
Factory default
F3-00
Lift and hoist equipment function Enable
0
~
1
0
0: Invalid
1: Valid
No.
Name
Set range
Factory default
F3-01
Release brake torque threshold
0%
~
300%
100%
F3-02
Release brake delay time
0.0s
~
3600.0s
3.0s
What the output
torque
is larger than the torque threshold and lasts the time in
F3-02
, it outputs
the release brake signal.
No.
Name
Set range
Factory default
F3-03
Brake frequency value
0.00Hz
~
50.00Hz
3.00Hz
F3-04
Brake delay time
0.0s
~
3600.0s
3.0s
When the output
frequency
is less than or equal to the frequency set in F3-03 during shutdown,
it will output brake signal after the time set in F3-04.
No.
Name
Set range
Factory default
F3-05
Emergency brake Enable
0
~
1
0
When the
function
is enabled, if the Stop command valid, it will output brake signal
immediately.
No.
Name
Set range
Factory default
F3-06
Release brake frequency value
0.00Hz
~
50.00Hz
3.00Hz
When the output frequency is greater than or equal to the set value and the output torque meets
the release condition, it outputs release brake signal.
No.
Name
Set range
Factory default
F3-07
Release brake time
0.0s
~
10.0s
3.0s
Release
brake
time for complete brake releasing smoothly.
Summary of Contents for SV800 Series