6 Function Parameters List SV800/SV800A User Manual
92
b0: Induction motor basic parameters
No.
Name
Content
Set value
b0-00
(1000H)
Induction motor selection
IM.SVC IM.VC IM.VF
0: The first motor
1: The second motor selection
Factory default
:
0
Range:0~1
b0-02
(1002H)
Motor self-learning type
IM.SVC IM.VC IM.VF
For induction motors, set the parameter and motor nameplate
parameters firstly. Then press MULT to perform motor
parameters self-learning. For IM.VF control mode, even it’s set
to 2, only DC mode self-learning is performed.
0: Do not perform self-learning
1: Perform DC mode self-learning
2: Perform full-mode self-learning
Factory default
:
0
Range:0~2
b0-03
(1003H)
Motor
temperature
compensation
function
selection
IM.SVC IM.VC
If the motor has temperature sensor built-in, the stator coil
temperature can be accurately detected, so as to the motor
parameters can be compensated well, For IM.VF control mode,
it does not require temperature compensation.
0
:
OFF
1
:
ON
Factory default
:
0
Range:0~1
b0-04
(1004H)
Motor temperature sensor
type
IM.SVC IM.VC IM.VF
0
:
PT100 (Default)
1
:
PT1000
Factory default
:
0
Range:0~1
b0-05
(1005H)
Motor
temperature
detection input selection
IM.SVC IM.VC IM.VF
0: Without input
1:AI1
2:AI2
3:AI3 (Reserve)
Factory default
:
0
Range:0~3
b1: First induction motor parameters
No.
Name
Content
Set value
b1-00
(1100H)
First motor rated power
IM.SVC IM.VC IM.VF
Vector control: Three grades less power to the rated power of
the inverter.
V/F control: 0 ~ rated power of frequency inverter
Determined with
the model
(kW)
b1-01
(1101H)
First motor rated voltage
IM.SVC IM.VC IM.VF
220V
:
140
~
230
400V
:
280
~
460
Determined with
the model
(V)
b1-02
(1102H)
First motor rated current
IM.SVC IM.VC IM.VF
Vector control: 40%-150% of inverter rated current
V/F control: 0%-150% of inverter rated current
Determined with
the model
(A)
b1-03
(1103H)
First motor rated speed
IM.SVC IM.VC IM.VF
Vector control: 25% to 100% of the maximum speed
V/F control: 400 r/min to 24000 r/min
Determined with
the model
(r/min)
b1-04
(1104H)
First motor pole number
selection
IM.SVC IM.VC IM.VF
Select the number of poles of the motor
Factory default
:
4
poles
Range:
2 poles ~12 poles
Summary of Contents for SV800 Series