7 Detailed function description SV800/SV800A User Manual
146
7.2.3 b2:The second induction motor parameters group
Under vector control, the second induction motor nameplate parameters , setting range and
factory default are as follows:
No.
Name
Set range
Factory default
b2-00
Second motor rated power
Three grades less power
~ Rated power
Determined with model
(kW)
b2-01
Second motor rated voltage
220V: 140V~230V
380V: 280V ~ 460V
Determined with model
(V)
b2-02
Second motor rated current
40% to 150% of the
rated current of the
inverter
Determined with model
(A)
b2-03
Second motor rated speed
E-00*25%
~
E-00
Determined with model
(r/min)
b2-04
Second motor pole number selection
2
~
12
4
b2-05
Second motor rated frequency
b2-03*b2-04/120
~
7.0+b2-03*b2-04/120
50.0Hz
b2-06
Second motor cooling method
0
~
1
0
b2-07
Second motor PG pulse number
60
~
3600
1024
For V/F control, the second induction motor nameplate parameters, setting range are as follows:
No.
Name
Set range
Factory default
b2-00
Second motor rated power
0~Rated power
Determined with model
(kW)
b2-01
Second motor rated voltage
220V: 140V~230V
380V: 280V ~ 460V
Determined with model
(V)
b2-02
Second motor rated current
0% to 150% of the
inverter rated current
Determined with model
(A)
b2-03
Second motor rated speed
400r/min~24000r/min
Determined with model
(r/min)
b2-04
Second motor pole number selection
2~12
4
b2-05
Second motor rated frequency
15.0 to the highest
frequency
50.0Hz
This group of parameters is the motor nameplate parameters. When setting, it is set according to
the rated value recorded on the nameplate or design sheet of the controlled motor. Please refer
to the first motor parameter description for details.
No.
Name
Set range
Factory default
b2-08
Second motor primary side resistance
Determined with the
model
Change with the model
(m Ω)
b2-09
Second motor secondary side resistance
Determined with the
model
Change with the model
(m Ω)
b2-10
Second motor leakage inductance
Determined with the
model
Change with the model
(m H)
b2-11
Second motor mutual inductance
Determined with the
model
Change with the model
(m H)
Summary of Contents for SV800 Series
Page 8: ......