Configuration
PASCA_TOUCHIT_EN
V02 | 07.2013
64
Cup warmer/hot water settings
Steam settings
Parameters: Cup warmer/hot water settings
Display text
Description
Setting range
Notes
301) Max. heating time
Sets the dispensing time of steam for the cup
warmer.
1-99 sec
The "13 Cup warmer" sy-
stem parameter is activa-
ted.
The dispensing options
are described in the "7 Dis-
pensing mode" parameter
under the "Common set-
tings".
Display text
Description
Setting range
Notes
501) Water quantity
Sets the dispensing time for the hot water
quantity.
1-99 sec
The "Hot water" system
parameter is activated.
The dispensing options
are described in the "7 Dis-
pensing mode" parameter
under the "Common set-
tings".
Parameters: Steam settings
Display text
Description
Setting range
Notes
901) Steam valve
Selection menu for the steam wand in use.
Super steam
Fine steam
"Super&Fine steam" must
be selected in the "12
Steam outlet" system
parameter.
The "11 Internal Steam
flush" system parameter is
deactivated.
902) Dosing time
Sets the steam output duration.
01-99.9 sec
The standard value is
90.0 sec.
A steam system is
selected in the "10 Steam
outlet" system parameter.
The dispensing options
are described in the "7 Dis-
pensing mode" parameter
under the "Common set-
tings".
903) Steam with sensor
Deactivates or activates the use of the tem-
perature sensor in the steam wand.
On/off
The standard value is
"ON".
"Auto steam", "Super
steam", "Fine steam" or
"Super-&Fine steam" is
selected in the "12 Steam
outlet" system parameter.