System
PASCA_TOUCHIT_EN
V02 | 07.2013
98
31) Center milk communication
Enables cleaning in the second machine of
the "Center Milk" milk system.
ON:
Cleaning is enabled in the second
machine.
OFF:
No communication between the ma-
chines.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
32) V19 steam cup heater
Actuation of the cup warmer valve.
ON:
The valve to the cup warmer opens
and steam is made available.
OFF:
The valve is closed and steam is not
made available.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
To actually output steam,
an additional mechanical
steam valve on the cup
warmer must be actuated.
33) V18 changeover
Changes the outlet to the "swan neck".
ON:
The valve is positioned to change the
outlet to the "swan neck".
OFF:
The valve is positioned for the stand-
ard beverage outlet.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
34) Rel7 relay twinmilk
Switches the additional relay for the "Twin
Milk" milk system.
ON:
The squeeze valve is switched on.
OFF:
The squeeze valve is switched off.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
35) PWM steam level
Output test of the level monitoring for the
steam boiler.
ON:
A "Level too low" output signal is sim-
ulated by the level monitoring.
OFF:
No output signal.
On/off
-
36) M8/M14 PWM milkpump
Pump speed regulation of the milk pump.
►
Enter the pump speed.
►
Confirm the entry.
The pump runs with the set speed.
►
Change the set value back to "0".
The pump is switched off.
0-100
"0"= switched off.
"100"=
max. Geschwindigkeit.
Parameters: Output test
Display text
Description
Setting range
Notes