PASCA_TOUCHIT_EN
V02 | 07.2013
97
System
25) main relay
Actuation of the steam boiler heating.
ON:
The steam boiler heating is switched
on.
OFF:
The steam boiler heating is switched
off.
On/off
The main relay switches
the control voltage. This
parameter influences the
automatic switch-on in the
"Output test" menu. If the
parameter is switched on
and off, no further output
tests are possible.
For further tests, switch
the parameter on or briefly
leave the "Output test"
menu and open it again.
26) Disable coin tester
Disables a connected coin tester.
ON:
The coin tester is disabled and not
functional.
OFF:
The coin tester with an activated pay-
ment system is ready for use.
On/off
-
27) buzzer
Actuation of the "buzzer" signal tone.
ON:
The signal tone is switched on.
OFF:
The signal tone is switched off.
On/off
-
28) M13 mixer motor
Actuation of the mixer motor for the powder
system.
ON:
The mixer motor is switched on.
OFF:
The mixer motor is switched off.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
29) V17 topping valve
Actuation of the valve for the powder system.
ON:
The valve to the powder system
opens and water flows.
OFF:
The valve is closed.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
30) Alarm output
Outputs an external error.
ON:
The valve to the powder system
opens and water flows.
OFF:
The valve is closed.
See "Configuration" - "Date/time/alarm" -
"External alarm display" for additional infor-
mation on external error signalling.
On/off
Only with the appropriate
machine equipment and
activated system parame-
ter.
Parameters: Output test
Display text
Description
Setting range
Notes