PASCA_TOUCHIT_EN
V02 | 07.2013
131
Troubleshooting
15) Over temperature coffee
16) Over temperature hot wa-
ter
A boiler temperature of 110°C°C or
higher was detected. If the raised tem-
perature persists, the "Klixon" safety
equipment is triggered.
The main board is faulty (069'468).
►
Replace the board.
The heating control is faulty (069'069).
►
Replace the heating control.
Temperature sensor (NTC) is faulty.
►
Check the electrical connections between the
sensor and main board.
►
Measure the resistance of the NTC sensor.
The following resistances must be measured at the
sensors at the corresponding temperatures:
•
25°C = 10,000 ohm
•
90°C = 910 Ohm
•
100°C = 678 ohm
►
If the measured value does not correspond to the
values specified here, the sensor must be re-
placed.
17) Over temperature steam
A boiler temperature of 145°C°C or
higher was detected. If the raised tem-
perature persists, the "Klixon" safety
equipment is triggered.
From software 5.14: This error is now only displayed
in the "Info" - "Counters and statistics" - "Errors and
Cleaning statistics" menu.
The main board is faulty (069'468).
►
Replace the board.
The heating control is faulty (069'069).
►
Replace the heating control.
The temperature sensor (NTC) is
faulty.
►
Check the electrical connections between the
sensor and main board.
►
Measure the resistance of the NTC sensor.
The following resistances must be measured at the
sensors at the corresponding temperatures:
•
25°C = 10,000 ohm
•
90°C = 910 Ohm
•
100°C = 678 ohm
►
If the measured value does not correspond to the
values specified here, the sensor must be re-
placed.
Display message
Cause
What to do