EN-133
9 | Menu | 9.4 | Input/Output Routing: The Global Routing Settings
EN
SurroundMonitor 11900 Series
•
Color Assignment
This key is used to select the color mode for the LRA
bargraph. In
Individual
mode, an individual color can be
assigned to each of the three LRA bar sections (low ran-
ge, comfort zone, high range). In
Swap
mode, the whole
LRA bar changes its color when the measured LRA value
exceeds the limits for the bargraph sections entered with
the
lRa low range
and
Comfort Zone
parameters.
Options:
Individual
,
Swap
. Default:
Individual
•
Grid color
This button displays the color selector for changing the
LRA grid color.
•
Label/numeric font color
This button displays the color selector for changing the
LRA numeric font color.
•
LRA low range color
This button displays the color selector for changing the
LRA low range color.
•
Comfort Zone color
This button displays the color selector for changing the
LRA Comfort Zone color.
•
LRA high range color
This button displays the color selector for changing the
LRA high range color.
•
Numerical enabled
This check box is used to activate or deactivate the nume-
rical LRA display.
•
Close
This button closes the page and returns you to the
loud-
ness Settings
menu page from where you entered the
LRA Group
menu.
•
LRA enabled
This checkbox is used to activate or deactivate the
lRa
instrument display.
•
Scale Range
This combo box is used to select the spread of the
lRa
instrument scale.
Options:
6 lu
,
10 lu
,
20 lu
,
30 lu
. The default is
10 lu
.
•
Mode
This combo box is used to select one of four modes
available for the
lRa
instrument. The
LRA Bar
mode
displays the LRA measurement on a bargraph meter with
the zero value at the bottom. The
MagiclRa
mode uses a
scale with a fixed centered zero position (corresponding to
the target level) where the LRA bar spreads symmetrically
from the
0
position and it‘s length is a measure for the
absolute LRA value.
Ma i
mode is a combination
of
lRa
and
integrated
(
i
) loudness measurements. The
LRA bar has a moving, relative zero position that is ancho-
red to the
integrated
value measured. The
Ma
i + num
mode adds a numerical display of the measured
LRA value inserted to the LRA bargraph.
Options:
LRA Bar
,
MagiclRa
,
Ma i
,
Ma
i + num
. Default:
LRA Bar
•
LRA Low Range
This parameter is used to select the spread of the LRA
bar‘s low (center) range.
Options: 1 to 20 LU in steps of 1 LU. The default is
2 lu
.
•
Comfort Zone
This key is used to select the spread of the LRA bar‘s
Comfort Zone. Please note that the Comfort Zone will only
be visible if this value exceeds the value entered for the
low range (see above).
Options: 1 to 20 LU in steps of 1 LU. The default is
4 lu
.
Summary of Contents for SurroundMonitor 11900 Series
Page 1: ...SurroundMonitor 11900 Manual ...
Page 2: ...SurroundMonitor 11900 ...
Page 3: ...DE SurroundMonitor 11900 Serie Bedienungsanleitung ...
Page 8: ...Sicherheitshinweise DE 6 SurroundMonitor 11900 Serie ...
Page 12: ...Inhaltsverzeichnis DE 10 SurroundMonitor 11900 Serie ...
Page 94: ...8 Instrumente Anzeigearten 8 15 Das BLITS Instrument DE 92 SurroundMonitor 11900 Serie ...
Page 156: ...9 Menü 9 12 Key Settings Menü Key Settings DE 154 SurroundMonitor 11900 Serie ...
Page 191: ...EN SurroundMonitor 11900 Series Operating Manual ...
Page 196: ...Safety Instructions Attention EN 6 SurroundMonitor 11900 Series ...
Page 200: ...Content EN 10 SurroundMonitor 11900 Series ...
Page 280: ...8 Instruments Display Modes 8 15 The BLITS Instrument EN 90 SurroundMonitor 11900 Series ...
Page 342: ...9 Menu 9 12 Key Settings The Key Settings Menu EN 152 SurroundMonitor 11900 Series ...