9 | Menu | 9.4 | Input/Output Routing: The Global Routing Settings
EN-130
SurroundMonitor 11900 Series
general ...
•
Scale
Depending on the selected
loudness
mode for the
Pro-
gram Meter
, the following scales are available:
ITU BS.1771 mode
•
ITU+9, ITU0
EBU R128 mode
•
EBU+9
•
EBU+18
•
EBU+9a
•
EBU +18a
aTSc a/85 mode
•
ITU+9
•
ATSC0
•
ATSC0a
ARIB mode
•
ATSC0
custom mode
•
EBU+9 (–18 to +9 LU)
•
EBU+18 (–36 to +18 LU)
•
EBU+9a (–41 to –14 LUFS)
•
EBU+18a (–59 to –5 LUFS)
•
EBU0 (–60 to 0 LUFS)
•
ITU+9 (–18 to +9 LU)
•
ITU0 (–30 to 0 LUFS)
•
ATSC0 (–60 to 0 LKFS)
•
ATSC0a (–30 to 0 LKFS)
•
Target Level
Depending on the selected
loudness
mode for the
Pro-
gram Meter
, the following target levels are preselected:
ITU BS.1771 mode
•
–24 LKFS
EBU R128 mode
•
–23 LUFS
aTSc a/85 mode
•
–24 LKFS
ARIB mode
•
–24 LKFS
custom mode
•
–23 LUFS
•
Filter
The filter used for all loudness measurements is
ITU BS.1770 (k)
Momentary ...
•
Window Time
With this combo box, the window time for the Momentary
bargraph is set.
Options (
custom
mode only): 100 to 1000 ms in steps
of 100 ms
For all loudness modes,
400 ms
is preselected.
Short ...
•
Integration Time
With this combo box, the integration time for the
Short
Term
bargraph is set.
Options: 1 to 20 s in steps of 1 s.
For all loudness modes,
3 s
is preselected.
integrated ...
•
Silence Gate
With this check box and combo box, the silence gate for
the
integrated
bargraph is configured. With the checkbox,
the gate is activated/deactivated; the combo box is used
to set the gate threshold.
Options:
on
/
off
, –80 LUFS/LKFS to –40 LUFS/LKFS.
For all loudness modes,
–70 LUFS/LKFS
is preselected.
The unit used depends on the selected loudness mode.
•
Relative Gate
With this check box and combo box, the relative gate for
the
integrated
bargraph is configured. With the checkbox,
the gate is activated/deactivated; the combo box is used
to set the gate threshold.
Options:
on
/
off
, –40 LU to 0 LU
For all loudness modes,
–10 LU
is preselected.
•
Alarm Threshold
With this list box, the Alarm threshold value in dB LU or
LKFS can be set. Signals exceeding this value are trigge-
ring the Alarm signalisation in the display.
Options: 0 to +9 LU/LUFS/LKFS in steps of 0.5 dB (de-
pending on the selected loudness mode + scale)
•
Alarm Hold
With this combo box, the hold time for the Alarm signalisa-
tion is set. Options:
1 s
,
5 s
,
Manual Reset
.
•
Operation indicator area
This list box sets the area where the indicator for the ope-
rating area is activated.
Options: –20 to 0 dB.
•
Grid Color
This button displays the color selector for changing the
color of the scale grid for the
M
,
S
and
i
bargraphs.
Summary of Contents for SurroundMonitor 11900 Series
Page 1: ...SurroundMonitor 11900 Manual ...
Page 2: ...SurroundMonitor 11900 ...
Page 3: ...DE SurroundMonitor 11900 Serie Bedienungsanleitung ...
Page 8: ...Sicherheitshinweise DE 6 SurroundMonitor 11900 Serie ...
Page 12: ...Inhaltsverzeichnis DE 10 SurroundMonitor 11900 Serie ...
Page 94: ...8 Instrumente Anzeigearten 8 15 Das BLITS Instrument DE 92 SurroundMonitor 11900 Serie ...
Page 156: ...9 Menü 9 12 Key Settings Menü Key Settings DE 154 SurroundMonitor 11900 Serie ...
Page 191: ...EN SurroundMonitor 11900 Series Operating Manual ...
Page 196: ...Safety Instructions Attention EN 6 SurroundMonitor 11900 Series ...
Page 200: ...Content EN 10 SurroundMonitor 11900 Series ...
Page 280: ...8 Instruments Display Modes 8 15 The BLITS Instrument EN 90 SurroundMonitor 11900 Series ...
Page 342: ...9 Menu 9 12 Key Settings The Key Settings Menu EN 152 SurroundMonitor 11900 Series ...