EN-81
8 | Instruments (Display Modes) | 8.12 | The HARDWARE STATUS Instrument
EN
SurroundMonitor 11900 Series
8.12 | The HaRdWaRe STaTuS instrument
The HARDWARE STATUS instrument is always displayed in
window 3. To set the focus on this instrument (indicated by a
highlighted frame around the window), simply press the
inS-
TR
key. With the focus on window 3, the HARDWARE STATUS
functions are displayed in the Toolbar (window 1).
Selecting the Hardware status monitor displays the status of
the AES/EBU receivers for all digital input sources and shows
which digital input is currently being used as the source of the
unit’s clock signal (reference sync signal source, marked with
white color in the instrument in window 3). If there is no signal
on the selected input for reference, the message “Selected re-
ference failure” is displayed in the Status Box in window 4. The
internal sampling rate selected on the
Audio System
menu
tab is used as clock signal if no digital signal is present at the
digital inputs.
NOTE -
There are no functions available!
8.12.1 | Changing parameters
Please proceed as follows to change the reference sync source:
Current sample frequency
Channel status of Digital 4 In/Out
connector
State of Sync Input, current sync
reference input
Channel status of Digital 3 In/Out
connector
Channel status of SDI input
legend:
locked: Dubbed AES receiver
forced: Reference signal is only
taken from this input
sig:
Signal present, but not in
sync
– –:
No valid signal present
Channels of
AES/EBU inputs
State of reference
sync input signal
6. Open the
A-D sample rate source
combo box and
select the option you need.
7. If you have selected
A-D follows reference below
, open
the combo box below and select the input you want to use
as reference sync source for the internal A-D converter.
8. Select the
Save & Exit
button to store the changes and
leave the menu. The
Save Global Settings?
menu page
is displayed.
9. Select
Save & Exit
again to store your edits and to return
to normal operation.
1. Press
Menu
. The unit changes to menu mode.
2. Select the
Audio System
menu tab. The
Global Audio
Settings
menu is shown.
3. Open the
Internal sampling rate if no external refe-
rence present
combo box and select the sampling rate
you need.
4. Open the
External reference source
combo box and
select your preferred source for the reference sync signal.
If you want to use the
Use Ref Input
option, please
connect the external reference signal to the
Ref Sync In
connector.
5. If you have a unit with HD/SD SDI deembedder interface
(S and SD versions), you can use the
SDI input
as refe-
rence. Check the
Force reference source to SDI input
if monitoring SDI
option if you want to use the
Sdi
input
every time you monitor SDI.
Summary of Contents for SurroundMonitor 11900 Series
Page 1: ...SurroundMonitor 11900 Manual ...
Page 2: ...SurroundMonitor 11900 ...
Page 3: ...DE SurroundMonitor 11900 Serie Bedienungsanleitung ...
Page 8: ...Sicherheitshinweise DE 6 SurroundMonitor 11900 Serie ...
Page 12: ...Inhaltsverzeichnis DE 10 SurroundMonitor 11900 Serie ...
Page 94: ...8 Instrumente Anzeigearten 8 15 Das BLITS Instrument DE 92 SurroundMonitor 11900 Serie ...
Page 156: ...9 Menü 9 12 Key Settings Menü Key Settings DE 154 SurroundMonitor 11900 Serie ...
Page 191: ...EN SurroundMonitor 11900 Series Operating Manual ...
Page 196: ...Safety Instructions Attention EN 6 SurroundMonitor 11900 Series ...
Page 200: ...Content EN 10 SurroundMonitor 11900 Series ...
Page 280: ...8 Instruments Display Modes 8 15 The BLITS Instrument EN 90 SurroundMonitor 11900 Series ...
Page 342: ...9 Menu 9 12 Key Settings The Key Settings Menu EN 152 SurroundMonitor 11900 Series ...