ENGLISH
75
Table 3 - Cooker regulations in the different use conditions
Starting
Open (7/8)
Open
Fast cooking
Open (7/8)
Closed
Slow cooking
Half open (3/4)
Closed
Fast heating
Open (7/8)
Closed
Slow heating
Closed (1/2)
Closed
condition
Primary
air
Starting
key
Picture 18 - Primary air regulation
On RV cookers the secondary air is fixed and
set so that the combustion is optimal and
the glass of the fire door is clean. When the
cooker is installed on a chimney with high
draught, it is possible to experience an ex-
cessive air inflow not limited by the draught
regulator. In this situation it is necessary to
restrict partially the air flow as indicated in
picture n.19, so that the excessive draught is
compensated. This regulation shall be done,
when necessary, only during the installation
of the cooker.
To make the regulation: open the fire door,
release the screws, scroll the regulating
plate and then fix the screws again. The
regulating plate scrolls horizontally and
opens or closes the air flow according to the
indicated direction.
Do not close completely the air flow be-
cause it may cause a not regular working of
the cooker that could make dirty the glass
of the fire door.
3.4
SECONDARY AIR REGULATION
Picture 19 - Secondary air regulation
Summary of Contents for RV 100
Page 1: ...Istruzioni d uso Gebrauchsanweisung Instructions Manuel d utilisation...
Page 2: ......
Page 125: ...123 Informazioni marcatura CE Marking Information...
Page 127: ...125 Informazioni marcatura CE Marking Information...
Page 128: ...126...
Page 129: ...127...
Page 130: ...128...
Page 131: ......
Page 132: ...Rizzoli 07 12 Rizzoli S r l info rizzolicucine it www rizzolicucine it...