Chimney must be dimensioned in a correct
way according to the type of cooker it is con-
nected with, minding the environmental and
general conditions of the place in which it is
placed. The section of the chimney must per-
mit the flow of the fumes produced by the
cooker without difficulties, but it must not
be too big otherwise the chimney will experi-
ence problems in heating itself and this may
generate problems like weak draught and
condensation. In table 1 it is indicated the rec-
ommended diameter for the flue according
to the model and to the height of the chim-
ney (H). The height of the chimney must be
enough to insure the draught necessary to
the chosen model. Bigger is the height of the
chimney, bigger is the draught; if the chimney
is lower than 4 metres, the correct working of
the cooker is not insured. The chimney must
not have tortuous parts, horizontal parts or
counterslope parts; the number of bends must
be reduced to minimum. In picture 4 you can
see some examples of good and bad chimney
connection.
2.4
DIMENSIONS AND CORRECT FORMS OF CHIMNEY
Picture 4 - Samples of correct and incorrect chimney connection
Picture 5 - H dimension for the sizing of the
flue
NO
H
YES
Table 1 - Indications for the dimension of the chimney according to its
height
entrance
130 mm
flue H < 4m
Draught not guaranteed
flue 4 m < H < 6m
160 mm
flue H > 6m
150 mm
Necessary depression
12 Pa
Model
RV
ø
ø
ø
ø
Summary of Contents for RV 100
Page 1: ...Istruzioni d uso Gebrauchsanweisung Instructions Manuel d utilisation...
Page 2: ......
Page 125: ...123 Informazioni marcatura CE Marking Information...
Page 127: ...125 Informazioni marcatura CE Marking Information...
Page 128: ...126...
Page 129: ...127...
Page 130: ...128...
Page 131: ......
Page 132: ...Rizzoli 07 12 Rizzoli S r l info rizzolicucine it www rizzolicucine it...