Introduction: Initial Configuration
American Science and Engineering, Inc.
3-38
MINI
Z
Operator Manual 342-9000-1 Rev. B ECCN EAR99
3.6.5
ASEI Scan Image Export File Format
The tablet can be used to export scan images in industry-standard graphics files:
•
JPG (JPEG) – Commonly used format that uses image compression to reduce file size.
•
PNG – Commonly used format that retains all original pixels and may be larger than a similar
JPEG file.
This selection applies to all exported files until changed again in this screen, or in the
Scan Monitor
Mode Screen
,
Review View Mode Screen
, or
Export Screen
. The setting is retained when the scanner
is turned off.
To change the file format used for exported image files, perform the following steps:
1. In the tablet
Home Screen
, tap the
Settings
button
. The Settings screen opens.
2. At the top of the screen, tap the
General
button. The
General
screen appears (see
Figure 5-11
).
3. In the
Image Format
option group, tap the button for the required format:
•
(Note text:
JPG
) Use JPEG format
•
(Note text:
PNG
) Use PNG format
This selection applies to all exported files until changed again in this screen, or in the
Scan Monitor
Mode Screen
or
Export Screen
.
3.6.6
ASEI Audible Warning
(Requires a connection to the Scanner)
The MINI Z has one audible X-ray generation indicator. It consists of an audible beep.
The quantity of beeps can be configured to match local governmental regulations:
•
Normal
– At the beginning of an X-ray emission, one beep. At the end of an X-ray emission, two
beeps. There are no beeps during the X-ray emission.
•
Extended
– At the beginning of an X-ray emission, five beeps. At the end of an X-ray emission,
two beeps. During the X-ray emission, one beep every second of time.
To set the warning type, use a supervisor-level user account to perform the following steps:
1. In the tablet ASEInspection Software
Home Screen
, tap the
Settings
button
. The
Settings
screen opens.
2. At the top of the screen, if necessary, tap the
General
button. The
General
screen appears (see
Figure 5-11
).
3. In the
Scanner
table, tap the
X-Ray beep
drop-down box to open the list.
4. Tap the required option. The list closes. It is not necessary to restart the scanner.