Maintenance: Storage and Shipping
American Science and Engineering, Inc.
11-4
MINI
Z
Operator Manual 342-9000-1 Rev. B ECCN EAR99
•
Access to the ASEInspection software application can be configured to require user name and
password.
•
Certain functions within the ASEInspection software application can be limited to supervisor-
level user accounts.
•
Access to the tablet operating system (Windows
®
) software is controlled by a separate
password.
•
The tablet can be removed from the physical location of the scanner unit, and secured in a
separate location.
•
Removable Access (Scanner Unit)
– There are several levels of security for the scanner unit:
•
The scanner unit requires a physical, removable key to enable the power-on switch. When the
scanner unit is powered-off, the key can be removed from the physical location of the scanner
unit, and secured in a separate location. When the scanner unit is powered-on, the key cannot
be removed from the scanner unit lockset.
•
The scanner cannot be operated with out a compatible tablet with the compatible
ASEInspection software installed. The tablet can be removed from the physical location of the
scanner unit, and secured in a separate location, and can have password access.
•
WiFi
– There are several levels of security for the WiFi connection
•
At any time, the Ethernet cable connection between the tablet and the scanner unit can be used.
When the Ethernet cable is in use, the WiFi connection is disabled.
•
At any time, the WiFi function on the tablet can be disabled, by placing the tablet into Airplane
mode. Enabling or Disabling Airplane mode requires access to the Windows operating system,
which is controlled by a separate password.
•
The WiFi identity of the individual scanner unit can be disguised by changing the SSID
identifier for the scanner. The SSID is changed using the tablet, and stored in the scanner unit
system. Access to the SSID fields requires a supervisor-level user account. (See
Section
3.6.3.4, Confidential SSIDs for Scanners
.)
•
Confidential SSIDs are hidden by default, so that SSIDs cannot be read “over the shoulder” of
the tablet operator. In order to display the custom SSID links, a tap of an additional innocuous
button is required.
•
The tablet can be connected to only one scanner unit at a time.
11.4
Storage and Shipping
When not in use, the system should be stored in the Rugged Transport Case provided with the system
(see
Figure 11-2
).
The system should be shipped only in the Rugged Transport Case provided with the system. A
returned merchandise approval must be issued by AS&E Field Service before the system is shipped to
AS&E or to an AS&E facility.