SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
725
Note:
•
The detection level set with
L4-03
is a signed value. The drive will only detect in one direction.
•
CLV and CLV/PM control use motor speed as the reference.
ON : The output frequency is less than the value of
L4-03
or is not higher than the value of
L4-03
+
L4-04
.
OFF : The output frequency is higher than the value of
L4-03
+
L4-04
.
Figure 12.94 Example of Frequency Detection 3 (value of L4-03 Is Positive)
Note:
shows the result of the configuration when
L4-07 = 2 [SpAgree Det.Selection = Always Detect]
. The default setting of
L4-
07
is
1 [No Detect@BB]
. When the speed agreement detection selection is
“
No Detection during Baseblock
”
, the terminal is deactivated
when the drive output stops.
■
16: FreqDetect 4
Setting
Function
Description
16
FreqDetect 4
The terminal activates when the output frequency is higher than the value of
L4-03 [SpAgree Det.Level(+/-)].
After the terminal
activates, the terminal stays on until the output frequency is at the value of
L4-03
-
L4-04
.
Note:
•
The detection level set with
L4-03
is a signed value. The drive will only detect in one direction.
•
CLV control uses motor speed as the reference.
ON : The output frequency is higher than the value of
L4-03
.
OFF : The output frequency is less than the value of “
L4-03
-
L4-04
”, or it is not higher than the
value of
L4-03
.
Figure 12.95 Example of Frequency Detection 4 (value of L4-03 Is Positive)
■
17: @Fast Stop
Setting
Function
Description
17
@Fast Stop
The terminal activates when the fast stop is in operation.
■
18: @KEBridethru
Setting
Function
Description
18
@KEBridethru
The activates during KEB Ride-Thru.
Note:
Refer to
“
KEB Ride-Thru function
”
for more information.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Summary of Contents for Q2A
Page 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Page 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Page 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...