4.8 Fine Tuning during Test Runs (Adjust the Control Function)
158
SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
4.8
Fine Tuning during Test Runs (Adjust the Control
Function)
This section gives information about the adjustment procedures to stop hunting or oscillation errors caused by
control function during a test run. Adjust the applicable parameters as specified by your control method and drive
status.
Note:
This section only lists frequently adjusted parameters. If you must adjust parameters that have a higher degree of precision, contact the
manufacturer.
◆
V/f Control and Closed Loop V/f Control
Table 4.17 Parameters for Fine Tuning the Drive (V/f Control and Closed Loop V/f Control Methods)
Issue
Parameter Number
Solution
Default
Setting
Recommended Setting
Hunting or oscillation at mid-range
speeds (10 Hz to 40 Hz)
n1-02 [HuntPrev Gain Setting
[
•
If torque is not sufficient with heavy loads, decrease
the setting value.
•
If hunting or oscillation occur with light loads,
increase the setting value.
•
If hunting occurs with a low-inductance motor, for
example a motor with a larger frame size or a high-
frequency motor, lower the setting value.
1.00
0.10 - 2.00
•
The volume of the motor
excitation sound is too high.
•
Hunting or oscillation at low
speeds (10 Hz or lower), or at
mid-range speeds (10 Hz to 40
Hz)
C6-02 [Carrier Frequency
Selection]
•
If the volume of the motor excitation sound is too
high, increase the carrier frequency.
•
If hunting or oscillation occur at low or mid-range
speeds, decrease the carrier frequency.
1 (2 kHz)
1 to upper limit value
•
Torque or speed response are
slow.
•
Hunting or oscillation
C4-02 [Trq Comp Delay
Time]
•
If torque or speed response are slow, decrease the
setting value.
•
If hunting or oscillation occur, increase the setting
value.
200 ms
100 - 1000 ms
•
Torque at low speeds (10 Hz or
lower) is not sufficient.
•
Hunting or oscillation
C4-01 [Trq Comp Gain]
•
If torque at low speeds (10 Hz or lower) is not
sufficient, increase the setting value.
•
If hunting or oscillation occur with light loads,
decrease the setting value.
1.00
0.50 - 1.50
•
Torque at low speeds (10 Hz or
lower) is not sufficient.
•
Large initial vibration at start up.
•
E1-08 [Mid A Voltage]
•
E1-10 [Min Output
Voltage]
•
If torque at low speeds (10 Hz or lower) is not
sufficient, increase the setting value.
•
If there is large initial vibration at start up, decrease
the setting value
•
E1-08: 15.0
V
•
E1-10: 9.0 V
Default s/- 5 V
In V/f control method, speed
precision is unsatisfactory.
C3-01 [Slip Comp Gain]
Set
Mot Rated Current (FLA)
,
Mot Rated Slip
, and
Mot
No-Load Current
, then adjust
C3-01
.
0.0 (no slip
compensation)
0.5 - 1.5
In Closed Loop V/f control method,
speed precision is unsatisfactory.
•
C5-01 [ASR PGain 1]
•
C5-02 [ASR ITime 1]
Adjust
C5-01, C5-02.
•
C5-01: 0.20
•
C5-02: 0.200
s
•
Proportional gain = 0.10 to
1.00
•
Integral time = 0.100 to
2.000 s
*1
Default value changes when
o2-04 [Drive KVA Selection]
and
C6-01 [ND/HD Duty Selection]
values change.
*2
Default value changes when
A1-02 [Control Method]
and
o2-04 [Drive KVA Selection]
values change.
*3
Default value changes when
A1-02 [Control Method]
and
E1-03 [V/f Pattern Selection]
values change.
*4
Recommended settings are for 200 V class drives. Multiply the voltage by 2 for 400 V class drives.
*5
In Closed Loop V/f Control, ASR only controls the output frequency. You cannot make a high-gain as in Closed Loop Vector control.
◆
Open Loop Vector Control Method
In Open Loop Vector Control, keep
C4-01 [Trq Comp Gain]
at its default setting (1.00). Do not adjust it.
If you cannot get speed precision during regeneration in Open Loop Vector Control, set
C3-04 = 1 [Slip
Comp@Regen = Enable>6 Hz]
.
Summary of Contents for Q2A
Page 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Page 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Page 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...