SIEPYEUOQ2A01G AC Drive Q2A Technical Manual
Setting Value
Function
10
USpeedAgree1
11
SpeedAgree2
12
USpeedAgree2
13
FreqDetect 1
14
FreqDetect 2
15
FreqDetect 3
16
FreqDetect 4
17
@Fast Stop
18
@KEBridethru
19
@ShortCBraking
1A
@BaseblockNO
1B
@BaseblockNC
1C
FreqRefSource
1D
RunCmdSource
1E
Motor2 Select
1F
Restart Enable
20
FltReset Active
21
PolePos Detection
22
Ext 24V Supply
2F
@SpeedSearch
30
@TorqueLimit
31
@SpdLim@Trq
32
TrqDetect1NO
33
TrqDetect1NC
37
TrqDetect2NO
Setting Value
Function
38
TrqDetect2NC
39
Timer Output
3C
Comparator 1
3D
Comparator 2
3E
PID Fbk Low
3F
PID Fbk High
4A
DC Bus Undervolt
4B
FreqRef Loss
4C
BrkRes Fault
4D
Motor OL1
4E
Drive PreOH
4F
PreOHTimeLim
60
BrkTransFault
61
BrkTransOH
62
Fan Alarm
63
Maintenance
65
WattH Pulse
66
MechWeakDetect
67
ModbusReg 1
69
ModbusReg 2
90 to 93
Q2pack DO1 to 10
A0 to A7
Q2pack ExDO1 to 8
100 to 1A7
Inverse output of 0 to A7
Sets an inverse output of the function for the MFDO.
Put a 1 at the front of the function setting to set inverse
output. For example, set
138
for inverse output of
38
[TrqDetect2NC]
.
*1
Inverse output is not available.
*2
You cannot set this parameter on models 4089 to 4675.
■
Extend MFDO1 to MFDO3 Function Selection
You can set MFDO functions to
bit 0 to bit 2 [Mbus MFDO1 to 3]
of Modbus register 15E0 (Hex.). Use
H2-40 to
H2-42 [Mbus 15E0h b0 Output Function to Mbus 15E0h b2 Output Function]
to select the function.
Figure 12.81 Functional Block Diagram of Modbus Multi-function Output
Table 12.46 Modbus MFDO Registers
Register No.
(Hex.)
Name
15E0
bit0
Mbus MFDO 1
bit1
Mbus MFDO 2
bit2
Mbus MFDO 3
Note:
•
Refer to H2-xx
“
MFDO Setting Values
”
for more information about MFDO setting values.
•
When you do not set functions to
H2-40 to H2-42
, set them to
0
.
■
Output of Logical Operation Results of MFDO
This enables the logical operation results of two MFDOs to be output to one MFDO terminal.
Use
H2-60, H2-63, and H2-66 [2NO-2CM 2nd Function, 3NO-3CM 2nd Function, 4NO-4CM 2nd Function]
to
set the function of the output signal for which logical operations are performed.
Summary of Contents for Q2A
Page 2: ...This Page Intentionally Blank 2 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 12: ...12 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 18: ...i 2 Legal Information 18 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 28: ...1 2 Features and Advantages of Control Methods 28 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 64: ...2 9 Installation Methods 64 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 166: ...4 9 Test Run Checklist 166 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 172: ...5 2 European Standards 172 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 173: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 173...
Page 174: ...5 2 European Standards 174 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 175: ...Standards Compliance 5 5 2 European Standards SIEPYEUOQ2A01G AC Drive Q2A Technical Manual 175...
Page 176: ...5 2 European Standards 176 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 258: ...6 2 Modbus Communications 258 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 356: ...8 7 Storage Guidelines 356 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...
Page 360: ...9 2 Disposal Instructions 360 SIEPYEUOQ2A01G AC Drive Q2A Technical Manual...