1-13
VIBXPERT 11.2010
The measurement device may only be operated if it is undam-
aged, dry and clean.
Operation and maintenance are to be performed only by
properly trained personnel.
Repairs to the device may be carried out only by a PRÜFTECH-
NIK-authorized service technician.
Only original spare parts and accessories may be used.
Only properly functioning, regularly-maintained electrical
equipment may be used. Any defects such as broken plugs or
loose sockets must be corrected immediately. Damaged cables
must be replaced by an authorized service technician.
Any alterations that affect device design or operating safety are
not permitted.
Environmental influences
Portable radio-based devices can interfere with proper function-
ing of the device when operated nearby. In case of doubt, check
the connecting cable between the device and its transducer.
Avoid exposing the device, its transducers and cables to
environmental conditions that exceed the tolerances listed in
the ‘Technical Data’ section at the rear of this manual.
Keep the protective caps on the connector sockets when they
are not in use to keep them clean.
Specific provisions for VIBXPERT with intrinsic safety
The following applies in potentially explosive environments:
When equipment to be measured is located in an explosive
environment, the intrinsically safe VIBXPERT EX (VIB
5.300 EX) and the appropriate intrinsically safe sensors and
accesories must be used.
For vibration measurements, you may only connect LineDrive
transducers of the VIB 6.1xx DEX model series, ICP-type
transducers of the VIB 6.172 XICP* model series or VIBCODE
transducers (VIB 8.660 HEX) to the measurement device.
Under no circumstances may you take measurements with the
following sensors: TIPTECTOR hand-held probe, LineDrive
transducers of the VIB 6.1xx EX, VIB 6.1xx REX model series.
Under no circumstances should you use the connection cable
for extra-low signal currents (VIB 5.434) and extra-low signal
voltages (VIB 5.433).
Under no circumstances should you recharge the battery.
Under no circumstances should you use the VIBXPERT case (VIB
5.329).
The device may only be connected outside the hazardous area
to a computer**. Use only the adapter VIB 5.330-UNV.
The protective film must be removed from the display.
Safety and operating notes
Attention!
** The computer meets the require-
ments of the Equipment Safety Act.
* only in gas-explosion hazardous area
and only with ICP-type sensor cable VIB
5.422.