3-39
VIBXPERT 11.2010
Recording
Ending the measurement recording
The measurement recording is ended when
-
the stop condition is fulfilled
-
the ESC button is pressed
-
the memory card is full
-
the maximum number of results is reached (65535).
Special cases
The recording function is used in a wide range of applications and is
intuitive in use. However, the following special characteristics should
be noted:
What happens if the device shuts down due to a fault?
If the battery should run out during measurement, the device saves
the measurement data prior to the emergency shut-off. If a fault
arises during measurement, the saved results are retained.
Shock pulse measurement
Before beginning recording, enter the normalization parameters. This
normalization then applies to the entire measurement duration.
Note: rpm-controlled recording is only possible without normalization.
Trending spectrum
To be able to record the measurement values in a trending spectrum,
the recording function is also available in the 'Machine template'
mode. Recording is configured and started as described in the
previous section.
Special characteristics:
-
The trending spectrum is integrated in a machine template
(OMNITREND software).
-
In addition to the trending spectrum, the machine template can
contain all measurement types permissible for the recording.
-
Recording is only possible in the template without a 'Production
test' (see also p. 3-14).
-
After the recording, all actions that are triggered automatically are
disabled in the template (e.g. starting the next task).
-
The recording configuration is not saved with the result.
-
Multiple datasets can be added to a file.