CALIBRATION PROCEDURE
NI PXIe-4141
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
(SMU)
This document contains the verification and adjustment procedures for the NI 4141. Refer to
for more information about calibration solutions.
Please review and become familiar with the entire procedure before beginning the calibration
process.
Contents
Required Software.............................................................................................................2
Related Documentation.....................................................................................................2
Password........................................................................................................................... 2
Calibration Interval........................................................................................................... 2
Test Equipment..................................................................................................................2
Test Conditions..................................................................................................................3
Calibration Overview........................................................................................................5
Self-Calibrating.................................................................................................................5
Voltage Output and Measurement.....................................................................................6
Current Output and Measurement.....................................................................................7
Remote Sense..................................................................................................................10
Adjusted Specifications...................................................................................................13
Self-Calibrating...............................................................................................................13
Initiating the Adjustment Session................................................................................... 14
Connecting and Configuring Equipment for Voltage Adjustment..................................14
Adjusting Voltage Measurement..................................................................................... 14
Connecting and Configuring Equipment for Current Adjustment..................................15
Adjusting Current Measurement.....................................................................................16
Connecting and Configuring Equipment to Adjust Residual Offset Voltage..................17
Adjusting Residual Voltage Offset..................................................................................17
Adjusting Residual Current Offset..................................................................................17
Closing the Adjustment Session..................................................................................... 17
Alternative to Adjustment Procedures............................................................................ 18
Reverification..........................................................................................................................18
Setting the Calibration Due Date............................................................................................ 18
Revision History..................................................................................................................... 19
NI Services..............................................................................................................................19