4-8
VIBXPERT 11.2010
Spectrum, Cepstrum
The measurement result is displayed in the upper half of the screen.
The measured time signal is displayed in the lower half of the screen
during the measurement. After the measurement, the following
information can be displayed after the measurement:
-
Max 10 (10 highest amplitudes in the spectrum)
-
Alarms
-
Frequency marker (only in Route / Template mode)
-
Trending parameters (only in TrendingSpectrum)
-
Time signal measured
-
Position of the main cursor
• Press the MENU key and select the 'Info' option.
• Click on the desired piece of information:
The data to be displayed by default after the measurment is set in
the display setup (see p. 4-18).
The active window pane is highlighted by a frame. Press the F key
to switch to the other window pane.
Max 10
Lists the 10 highest amplitudes in the spectrum. Click on an entry to
set the cursor to the corresponding line of the spectrum. You can sort
the list for amplitude or frequency in ascending or descending
sequence. To do so, click on the respective column title.
Results
Note
F
In-depth information is given in the
section 'Measurement Tasks' (Ch. 5).
lower display field is active
Spectrum: Amplitude, Envelope , Order
Trending, TrendingEnvelope , Cepstrum
Left:
Spectrum & time waveform
Right:
Additional information
Summary of Contents for VIB 5.300 EX Series
Page 170: ...6 24 VIBXPERT 11 2010 Decleration of conformity ...