Getting started - Basic settings
Transducers
The transducer menu (see below) contains all of the functions and
presettings for the transducer. Click on 'Transducers' to open the
menu.
Available transducers in VIBXPERT
The measurement-relevant parameters for many transducers are
stored in VIBXPERT. Consequently, when putting together a mea-
surement task, it is only necessary to select the transducer required
for the measurement.
The transducer list (see below) in the 'Available transducer' menu
contains all the factory-configured and user-defined transducers.
Under certain circumstances, this list can be very extensive.
Preselecting available transducers
As it is probable that not all the transducers stored in VIBXPERT will
be used, the choice can be restricted to those transducers that are
available to the user. When setting up the measurement tasks,
VIBXPERT only offers the choice of the preselected transducers as
standard:
• Click on each of the relevant transducers in the list so that these
are marked with a cross.
Displaying the transducer application
To check in which measurement task(s) the individual transducers
are used, proceed as follows:
• Mark the relevant transducer in the list.
• Press the MENU key.
• Click on 'Usage' (see below).
A list appears to show the measurement tasks that are measured with
the transducer.