4-17
VIBXPERT 11.2010
Display setup
C1. Display Setup for measurement: Coastdown, Orbit, Phase
The following sections C and D only describe the parameters specific
to the measurement type. Global display parameters, such as 'Zoom'
and 'Cursor', can be found in sections A and B.
S
HOW
OVERALL
(C
OASTDOWN
- O
VERALL
VALUE
): The results screen displays
two diagrams, RMS value and peak value in dependence on the
RPM. Select the peak value which is to be displayed as standard.
P
LOT
TYPE
(C
OASTDOWN
- P
HASE
): The runup / coastdown curve can be
displayed as a
Bode or Nyquist plot
.
Orbit
(polar representation)
and
single signals
(Cartesian representation) can be selected for
the shaft movement. The
AC only
option shows the AC compo-
nente of the signal.
S
HOW
AMPLITUDE
AS
(C
OASTDOWN
CURVE
- P
HASE
VECTOR
): Amplitudes can be
displayed as an RMS value or a peak value (
0-p
).
C
ONTINUOUS
PHASE
(C
OASTDOWN
- P
HASE
WITH
B
ODE
PLOT
): The scale of the
phase axis begins at 0° and ends at 360°. If the curve runs beyond
the 360° mark during the measurement, it is continued unchanged
at 0° (
No
). If you select the
Yes
option, the phase axis continues
beyond 360° - beginning again at 0° - and the phase progression is
continually displayed.
S
PEED
M
ARKER
(O
RBIT
): See section B1.
A
NGLE
DIRECTION
(C
OASTDOWN
C
URVE
- P
HASE
VECTOR
, P
HASE
MEASUREMENT
):
This parameter is primarily used in displaying the coastdown
curve in the Bode plot and determines the direction of rotation of
the phase measurement. Select whether the phase should be
displayed
before
or
after
the trigger mark.
A
NGLE
TYPE
(C
OASTDOWN
- P
HASE
, P
HASE
MEASUREMENT
): The angle type
indicates whether the
synchronous phase
is measured or whether
the phase is displayed in the
mathematically
correct sense.
C
ONTINUOUS
MEASUREMENT
(
LIVE
MODE
): see section X on page 4-15.
Left:
Display setup for Coastdown
(Phase-RPM)
Right:
Display setup for shaft vibration
(Orbit)