MGC Administrator’s Guide
3-33
For the system to recognize the PRI line that connects to the Net-T1/Net-
E1
Network Interface card you have to assign the PRI line's circuit ID as
defined in the ISDN Network Services to the Net-T1/Net-E1
Network
Interface module.
6.
Fill in the
Span A
section as follows:
a.
Clear the
Null Configuration
check box to indicate that a PRI line
is connected to the Network Interface Module.
b.
In the
Circuit ID
box, enter the circuit ID as defined in the
Network
Service-Span and Phones
dialog box. According to the selected
Circuit ID, an ISDN Network service is assigned to the network
card. Each span can be assigned a different ISDN Network Service.
c.
Click
Apply
.
The name of the network service appears in the
Service Name
box.
7.
Click
OK
.
To configure the Net-T1/Net-E1 ISDN network span as primary or
backup clock:
1.
In the
Browser
pane, click the slot containing the ISDN Network
Interface module (PRI) to configure in the
Status
pane, or click the plus
[+] icon next to the
Card
icon to expand its units tree.
If you clicked the slot, the module’s units and configuration are
displayed in the
Status
pane. If you expanded the units tree, the units are
displayed in the
Browser
pane.
Summary of Contents for MGC Administrator
Page 1: ...MGC Administrator s Guide Version 7 5 ...
Page 4: ......
Page 50: ...Chapter 2 Software Installation 2 32 ...
Page 408: ...Chapter 6 Defining Operators 6 12 ...
Page 482: ...Chapter 7 Configuring the Gateway 7 74 ...
Page 496: ...Chapter 8 Audio and Video Conversion Tools 8 14 ...
Page 534: ...Appendix B PPP Setup B 24 ...