MGC Administrator’s Guide
5-125
The flag may be set to one of the following options:
•
NO
(Logger mechanism is not activated automatically on card startup)
•
YES
(Logger mechanism is activated automatically on card startup)
In addition, the AUTO_AUDIO_PLUS_LOGGER flag must be set to NO:
•
NO
(Logger mechanism is activated only as a response to IP Terminal
command)
The files are created sequentially, cyclically, when the 100
th
file overwrites
the first file and so on. Recommended mode is
NO
(manual card monitor).
The file names are generated automatically, containing the following
components:
•
Text:
ap_logger
•
Board ID number
•
Unit ID number
•
A serial number between 0 and 99, ascending sequentially
For example, a file could be named:
ap_logger 4 2 03
where
4
is the Board
ID number,
2
is the Unit ID number and
03
is the serial number between 0
and 99.
Manual creation of the Audio+ logger files:
In the
IP Terminal
window, type the command:
ap_logger <board_id> <unit_id>
Where <
board_id
> is the Audio+ board slot number and <
unit_id
> is the
mapped unit ID (0 for Card Manager).
For example, type
ap_logger 5 0
The file is stored in the MCU under the directory
7.256\mcu\ap_log\
. This
folder is automatically created by the system if it does not exist on the MCU.
Summary of Contents for MGC Administrator
Page 1: ...MGC Administrator s Guide Version 7 5 ...
Page 4: ......
Page 50: ...Chapter 2 Software Installation 2 32 ...
Page 408: ...Chapter 6 Defining Operators 6 12 ...
Page 482: ...Chapter 7 Configuring the Gateway 7 74 ...
Page 496: ...Chapter 8 Audio and Video Conversion Tools 8 14 ...
Page 534: ...Appendix B PPP Setup B 24 ...