MGC Administrator’s Guide
A-11
FAN
_1_
FAILURE
major
Applicable to MGC-25 only.
Fan one failed.
FAN
_2_
FAILURE
major
Applicable to MGC-25 only.
Fan two failed.
GATE
_
KEEPER
_
ERROR
minor
Occurs when an attempt to register
with the Gatekeeper has failed.
GATEKEEPER
_
MESSAGE
system
message
Returns the code:
REGISTRATION_SUCCEEDED, the
card succeeded in registering to the
Gatekeeper.
INSUFFICIENT
_
TDM
_
ALERT
major
Failure occurs during TDM time slot
(TSS) allocation when the requested
number of TSS are not available, and
the corresponding resources cannot be
used.
For each port in the MCU TSS
interaction between cards is conducted
using a TDM (Time Division Multiplex)
method, where two types of TSS
allocation are used:
•
Static
•
Dynamic
LINE
_
PM
_
ERROR
minor
Occurs when there is a problem with
performance monitoring. All network
issues are notified via the Net card.
LOW
_
MEMORY
_
ALERT
major
There is a high fragmentation problem,
which has caused a memory overload.
MCU
_
VERSION
_
IS
_
NOT
_
PERMITTED
major
Dongle error status—no permission
granted for MCU version.
MORE
_
THAN
_
ONE
_
CLOCK
_
SOURCE
_
TYPES
minor
Occurs when more than one flag in the
MCU CLOCKING section of the
system.cfg file is configured to
YES
.
Table A-6: General Fault Descriptions (Continued)
Code
Level
Description
Summary of Contents for MGC Administrator
Page 1: ...MGC Administrator s Guide Version 7 5 ...
Page 4: ......
Page 50: ...Chapter 2 Software Installation 2 32 ...
Page 408: ...Chapter 6 Defining Operators 6 12 ...
Page 482: ...Chapter 7 Configuring the Gateway 7 74 ...
Page 496: ...Chapter 8 Audio and Video Conversion Tools 8 14 ...
Page 534: ...Appendix B PPP Setup B 24 ...