104
KENR6932
Disassembly and Assembly Section
g01339597
Illustration 199
g01339688
Illustration 200
2.
Loosen clamps (11) and remove hose (12) from
cover (1) and from tube (13).
3.
Carefully pry cover (1) from breather body (4).
Note:
Note the orientation of the outlet.
4.
Remove gauze (2) from breather body (4).
5.
Remove O-ring seal (3) from breather body (4).
6.
Use Tooling (A) in order to unscrew breather body
(4) from adapter plate (8).
7.
Remove O-ring seal (5) from breather body (4).
8.
Remove bolts (6) and washers (7) from adapter
plate (8).
9.
Remove adapter plate (8) from valve mechanism
cover (10).
10.
Remove O-ring seal (9) from adapter plate (8).