Parker EME
Compax3 device description
192-120103 N13 C3I20T11 / C3I32T11 December 2010
83
STO delay times
Input Channel 1
(Energize)
Speed
Feedback
Channel 1
t_deceleration
(configurable in Compax3)
t_delay_time
(configurable in UE410)
t_delay_relay_ch2
Input Channel 2
(ENAin)
Feedback
Channel 2
The deceleration time
t_deceleration
depends on the configuration of the
Compax3. It must be configured so that oscillation free bringing to standstill is
possible, depending on the mechanical load. The delay time
t_delay_time
must be
set in the safety control device UE410 so that
t_delay_time
>
t_deceleration
.
Only after the elapsing of the relay delay
t_delay_relay_ch2
, the STO function is
completely activated. The relay delay time
t_deay_relay_ch2
is 15 ms.