Setting
up Compax3
C3I20T11 / C3I32T11
210
192-120103 N13 C3I20T11 / C3I32T11 December 2010
The framed objects are coupling objects for Compax3 - Compax3 coupling via
HEDA.
Please note that the corresponding controller components must be deactivated for
the coupling:
When coupling the velocity (O2219.14): O100.1 or O100.2=1063 (see object
description)
When coupling via current (O2220.2): O100.1 or O100.2=1031 (see object
description)
O100.1 is only copied into O100.2 upon activation of the controller, the controller
can be influenced in active state with the aid of O100.2
Changing objects O100.1 and O100.2 may cause the control to be deactivated!
Protect dangerous areas!
External command value
During external setpoint specification, please respect the structure images for
electronic cams or gearboxes for
signal filtering with external setpoint
specification
(see on page 233) !
Complementary structure for
load control
(see on page 158).
Compax3
controller structures
(see on page 202, see on page 208, see on page
Symbol
Description
p
K
Proportional term
signal is multiplied with K
p
T1
First order delay component (P-T1 term)
K
I
Integration block (I-block)
Kp,T
N
PI-block
Limitation block (signal limitation)
f
f
B
d
Notch filter (band elimination filter)
Addition block
blue
description
Optimization objects
(simple pointer line)
red
description
Status objects
(pointer line with vertical stroke)
Caution!