Setting
up Compax3
C3I20T11 / C3I32T11
178
192-120103 N13 C3I20T11 / C3I32T11 December 2010
Motor continuous usage
In this chapter you can read about:
Linearized motor characteristic lien for different operating points ................................... 178
This kind of monitoring watches over the continually deliverable torque (continuous
current). This continuous current depends on the velocity and is acquired online
from the linearization of the motor characteristic line.
Linearized motor characteristic lien for different operating points
Nominal point
0
500
1000
1500
2000
2500
3000
0
0.5
1
2
2.5
3
3.5
S1 65°C DT
S3 50% 65°C DT
S3 20% 65°C DT
S1 105°C DT
[A]
[1/min]
2
2
I
0
I
N
n
N
1
I
0
:
Standstill current
1:
Nominal point
I
N
:
Nominal current (defined in the MotorManager)
n
N
:
Nominal Speed
2:
Forbidden range
For monitoring the continuous utilization, the linearized characteristic line between
I
0
und I
N
/ n
N
is used as a threshold.