Parker EME
Introduction
192-120103 N13 C3I20T11 / C3I32T11 December 2010
21
Corresponding to the specifications of the terminal clamp with a temperature range
of up to 75°C.
Signal lines and power lines should be installed as far apart as possible.
Signal lines should never pass close to excessive sources of interference
(motors, transformers, contactors etc.).
Do not place mains filter output cable parallel to the load cable.
1.7.1.3
Additional conditions of utilization
Operation with standard motors.
Use only with aligned controller (to avoid control loop oscillation).
Connect the filter housing and the device to the cabinet frame, making sure that the
contact area is adequate and that the connection has low resistance and low
inductance.
Never mount the filter housing and the device on paint-coated surfaces!
For CE and UL conform operation of the Compax3S300V4, a mains filter is
compulsory:
400 VAC / 0.740 mH certified in accordance with EN 61558-1 bzw. 61558-2-2
We offer the mains filter as an accessory: LIR01/01
Make sure to use only the accessories recommended by Parker
Connect all cable shields at both ends, ensuring large contact areas!
This is a product in the restricted sales distribution class according to EN
61800-3. In a domestic area this product can cause radio frequency
disturbance, in which case the user may be required to implement
appropriate remedial measures.
Cable for Compax3H
Cable installation:
Motors:
Control:
Grounding:
Compax3S300V4
Accessories:
Warning: