![Parker Compax3 C3I20T11 Operating Instructions Manual Download Page 376](http://html1.mh-extra.com/html/parker/compax3-c3i20t11/compax3-c3i20t11_operating-instructions-manual_3811584376.webp)
Compax3
Accessories
C3I20T11 / C3I32T11
376
192-120103 N13 C3I20T11 / C3I32T11 December 2010
9.4
External braking resistors
In this chapter you can read about:
Permissible braking pulse powers of the braking resistors ............................................. 377
Dimensions of the braking resistors ............................................................................... 387
Danger!
Hazards when handling ballast resistors!
Housing temperature up to 200°C!
Dangerous voltage!
The device may be operated only in the mounted state!
The external braking resistors must be installed such that protection against
contact is ensured (IP20).
Install the connecting leads at the bottom.
The braking resistors must be grounded.
We recommend to use a thrust washer for the BRM13 and BRM14.
Observe the instructions on the resistors (warning plate).
Please note that the length of the supply cable must not exceed 2m!
Ballast resistors for Compax3
Ballast resistor
(see on page
Device
Rated output
BRM08/01 (100
Ω
)
Compax3S025V2
Compax3S015V4
Compax3S038V4
60 W
BRM05/01 (56
Ω
)
Compax3S063V2
Compax3S075V4
180 W
BRM05/02 (56
Ω
)
Compax3S075V4
570 W
BRM10/01 (47
Ω
)
Compax3S150V4
570 W
BRM10/02 (470
Ω
)
Compax3S150V4
1500 kW
BRM04/01 (15
Ω
)
Compax3S150V2
Compax3S300V4
PSUP20D6
570 W
BRM04/02 (15
Ω
)
Compax3S150V2
Compax3S300V4
PSUP20D6
740 W
BRM04/03 (15
Ω
)
Compax3S300V4
PSUP20D6
1500 W
BRM09/01 (22
Ω
)
Compax3S100V2
570 W
BRM11/01 (27
Ω
)
Compax3H0xxV4
3500 W
BRM13/01 (30
Ω
)
PSUP10D6
PSUP20D6**
500 W
BRM14/01 (15
Ω
)
PSUP10D6*
PSUP20D6
500 W
BRM12/01 (18
Ω
)
Compax3H1xxV4
4500 W
*for PSUP10D6 2x15
Ω
in series
**for PSUP20D6 2x30
Ω
parallel