Technical
Characteristics
C3I20T11 / C3I32T11
418
192-120103 N13 C3I20T11 / C3I32T11 December 2010
UL certification for Compax3S
conform to UL:
according to UL508C
Certified
E-File_No.: E235342
The UL certification is documented by a "UL" logo on the
device (type specification plate).
“UL” logo:
UL-approval for PSUP/Compax3M
conform to UL:
according to UL508C
Certified
E-File_No.: E235342
The UL certification is documented
by a “UL” logo on the device (type
specification plate).
Insulation requirements
Enclosure rating
Protection class in accordance with EN 60664-1
Protection against human contact
with dangerous voltages
In accordance with EN 61800-5-1
Overvoltage category
Voltage category III in accordance with
EN 60664-1
Degree of contamination
Degree of contamination 2 in accordance with
EN 60664-1 and EN 61800-5-1
Environmental conditions Compax3S and Compax3H
General ambient conditions
In accordance with
EN 60 721-3-1 to 3-3
Climate (temperature/humidity/barometric
pressure): Class 3K3
Permissible ambient temperature:
Operation
storage
transport
0 to +45 °C
class 3K3
–25 to +70 °C
class 2K3
–25 to +70 °C
class 2K3
Tolerated humidity:
no condensation
Operation
storage
transport
<= 85% class 3K3
<= 95% class 2K3
<= 95% class 2K3
(Relative humidity)
Elevation of operating site
<=1000m above sea level for 100% load ratings
<=2000m above sea level for 1% / 100m power
reduction
please inquire for greater elevations
Mechanic resonances:
EN 60068-2-6 (sinusoidal excitation)
Sealing
Protection type IP20 in accordance with
EN 60 529