59
3-2 Start-up & Termination
WARNING
• It is obligated by IEC/FDA/JIS that laser products shall incorporate a key-
actuated master control. Actuation of this laser marker is basically controlled
by the key switch located on the front of the controller box. However, in
considering situations when the laser marker is operating as a part of a larger
system, the laser marker turns on if the key switch is already in ON position,
and power is supplied. In this case, be sure that the external system controls
the operation of the laser marker with a key-actuated master control.
3-2-1 Start-up procedure
1.
Setup the laser marker connecting head, controller and interfaces.
Refer to “2-5 Connecting Laser Marker” (P.47).
2.
Turn ON the key switch of the controller.
The display panel on the controller lights and shows “PLEASE
WAIT”.
3.
The system startup completes approximately after 10 seconds.
The file number is displayed on the panel.
ワㄐㄕㄊㄆ
• Do not set the key switch to OFF until system startup has been completed.
• In case of turning ON the power supply after turning OFF, leave the interval five seconds or more between ON and OFF.
• In case the file No. is not displayed on the panel after 10 second passes since turning on the key switch, contact our
sales office or representatives.
4.
To configure and control by the PC configuration software, start Laser Marker NAVI smart and establish an online
connection with the laser marker.
• In Windows 10, open the start menu and select “Panasonic-ID SUNX Laser” - “Laser Marker NAVI smart”.
• In Windows 8.1, open the start menu and select “All Apps” - “Panasonic-ID SUNX Laser” - “Laser Marker NAVI
smart”.
Refer to “3-3-3 How to establish online connection” (P.67).
ヱヰヸユ
ン
ON
OFF
ME-LPRF-SM-11
Summary of Contents for LP-RF Series
Page 17: ...1 Product Overview ME LPRF SM 11...
Page 34: ...2 Laser Marker Installation ME LPRF SM 11...
Page 57: ...3 Operation Method ME LPRF SM 11...
Page 81: ...4 External Control Using I O ME LPRF SM 11...
Page 126: ...5 External Control by Communication Commands ME LPRF SM 11...
Page 135: ...6 Link Control with External Devices ME LPRF SM 11...
Page 160: ...7 Maintenance ME LPRF SM 11...
Page 186: ...Troubleshooting ME LPRF SM 11...
Page 214: ...Index ME LPRF SM 11...
Page 216: ...216 USB 32 55 W Warning 205 ME LPRF SM 11...
Page 217: ......