202
ERROR
CODE
Description
Measures *1
E159 *4
E231 - E236 *4 Network unit error.
Check if the optional network unit is installed to
the controller correctly.
E200 - E201
INTERLOCK safety relay is out of order.
Contact our sales office or representatives.
E205 - E207
• Abnormality occurs on the internal shutter.
• Signal cable is not connected properly.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
E220
Laser head housing is open.
Contact our sales office or representatives.
E225 *4
Fiber unit is detached.
Install the fiber unit properly by following the
procedures described in the “Setup/Maintenance
Guide”.
E250 - E252
E260 - E261
E264 - E265
• An error has occurred to the laser oscillator.
• A power supply voltage error was detected in
the laser oscillator.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
• For LP-RC series:
Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
E262 *4
Temperature error in laser oscillator.
• Check if the ambient temperature of the
laser marker is not exceeding the range of its
specification.
• Make sure air-cooling fan operates.
• Remove the dust and contamination in the
air intake and exhaust port, and clean the air-
cooling part such as fan and filter.
• When not recovered, contact our sales office
or representatives.
E263 *4
Detected unintended-irradiation.
Contact our sales office or representatives.
E270 - E275
E277
E280 - E285
E287
• An error has occurred to the galvano scanner
of the head.
• Incorrect connection of signal cable or unit
power cable.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cable and various
signal lines, and then restart the laser marker.
E286 *2, *3
Marking data are too detailed for the scan speed
configured.
Decrease the scan speed.
E290 - E292
An error has occurred to the Z-axis adjustment
module.
Check the connection of the cable and various
signal lines, and then restart the laser marker.
ME-LPRF-SM-11
Summary of Contents for LP-RF Series
Page 17: ...1 Product Overview ME LPRF SM 11...
Page 34: ...2 Laser Marker Installation ME LPRF SM 11...
Page 57: ...3 Operation Method ME LPRF SM 11...
Page 81: ...4 External Control Using I O ME LPRF SM 11...
Page 126: ...5 External Control by Communication Commands ME LPRF SM 11...
Page 135: ...6 Link Control with External Devices ME LPRF SM 11...
Page 160: ...7 Maintenance ME LPRF SM 11...
Page 186: ...Troubleshooting ME LPRF SM 11...
Page 214: ...Index ME LPRF SM 11...
Page 216: ...216 USB 32 55 W Warning 205 ME LPRF SM 11...
Page 217: ......