4.1.3 Supervisory Monitor (ACD) Control
–
Monitor Control & Execute
–
ACD Report Analysis
Monitor Control & Execute
A user designated as an ACD Supervisor or Administrator can specify certain ICD groups to monitor and
configure the monitoring settings. Finally, the user can start the monitor.
To configure the monitor settings and start monitoring
You can configure the monitor control settings in the
Group Monitor
of the
ICDG Management
in Web
Maintenance Console.
1.
On the left side of the screen, click
Users
®
ICDG Management
®
Group Monitor
.
2.
Select an ACD Supervisor from the
Supervisor selection
drop-down list.
3.
On the
Layout
of the
Basic Settings
, select the layout for showing the monitor results.
4.
Select the ICD Group that you want to monitor from the
Select ICD Group
drop-down list.
5.
On the
Options
, you can change the following settings for the monitor screen:
Item
Description
Value
Member Status View Mode
Select the display mode for
members’ status.
Standard
,
Simple
Highlighted
Display
Settings
Number of Current
Waiting Calls (1-30)
Specify the number of waiting
calls at which the
Current
Waiting Calls
display is
highlighted.
1–30
Waiting Time (0-10
min/10 sec)
Specify the waiting time at
which the
Longest Waiting
Time
display is highlighted.
0–10 minutes
Colour Mode
Select the colour to use to
highlight items on the screen.
Mode 1
,
Mode 2
,
Mode 3
Blinking
Select whether items that are
highlighted on the screen
blink.
Enable
,
Disable
6.
Click
Apply
.
7.
When you finish configuring the settings, click
Start Monitor
to start monitoring the selected ICD group.
8.
Click
Close
.
9.
Click
OK
.
ACD Report Analysis
You can specify which items to include in the monitor result report, the style in which to display the report
profile, and the output format.
1.
On the left side of the screen, click
Users
®
ICDG Management
®
ACD Report
.
2.
Select an ACD Supervisor from the
Supervisor selection
drop-down list.
To load an ACD report
a.
Click
Report Profiles
.
b.
Select the
Profile Name
.
User Manual
355
4.1.3 Supervisory Monitor (ACD) Control
Summary of Contents for KX-NS300
Page 252: ...Table 1 Standard mode for RU UC model 252 User Manual 1 14 2 Using the Directories...
Page 253: ...Table 2 Option mode User Manual 253 1 14 2 Using the Directories...
Page 254: ...Table 2 Option mode for NE model 254 User Manual 1 14 2 Using the Directories...
Page 255: ...Table 2 Option mode for Greece User Manual 255 1 14 2 Using the Directories...
Page 256: ...Table 2 Option mode for RU UC model 256 User Manual 1 14 2 Using the Directories...
Page 266: ...266 User Manual 1 15 1 Cellular Phone Features...
Page 306: ...306 User Manual 2 2 2 Message Manager Features...
Page 350: ...350 User Manual 3 2 1 User Programming...
Page 358: ...358 User Manual 4 1 3 Supervisory Monitor ACD Control...
Page 387: ...User Manual 387 Notes...