237
V530-R160
Operation Manual
SE
C
T
IO
N
8
Se
rial
Int
e
rf
ac
e (Hos
t Link)
SECTION 8
Communication with the Host
The screen for setting the communications specifi-
cations will be displayed.
5.
Make the settings for each item.
6.
Select
End
.
The setting will be registered and the screen in
4.
will return.
The asterisk (*) indicates the default setting.
Note 1
: Since communications speeds higher than 20 kbps are not defined with the RS-232C standard,
depending on the cable length, if
38400
bps or a higher setting is selected it may not be possible to
perform communications properly.
If this happens, change the setting to
19200
bps or lower.
Note 2
: The XMODEM (-1K) protocol is not supported.
Set Items and their details
Item
Selection
Interface
RS-232C*, RS-422
Baud rate (See note 1.)
2400, 4800, 9600, 19200, 38400*,
57600,115200 (bps)
The same settings as those of the
Programmable Controller
Data length
7, 8* (bit)
Parity bits
None*, Odd, Even
Stop bits
1*, 2 (bit)
Header
None*, STX, ESC
Footer
CR*, LF, CR+LF, ETX
FCS
OFF*, ON
Mode
Select
Host Link
. (Normal*, Host link)
Protocol (See note 2.)
XMODEM*, ZMODEM