Cha
nging Sce
nes (
S
cen
e Func
tion)
V530-R160
Operation Manual
SECTION 6
Other Functions
Changing Scenes (Scene Function)
When two cameras are used, when the shutter speed differs according to the read code, or when the
type of the read code (DataMatrix/QRCode) differs, use the scene function.
The different situations in which readings are performed are called “scenes” and the reading conditions
set in
SET
Mode are called “scene data.” The scene function can be used to set 10 types of reading
conditions. If reading conditions change, simply switch to change to a different reading scene.
The normal limit of 10 scenes may not be possible for some settings if there is insufficient memory.
A message will appear on the screen if there is insufficient memory. Delete unnecessary patterns.
Setting Reading Conditions for Different Codes (Changing
Scenes)
Use the scene changing function to switch between different reading conditions for different read-
ing conditions or reading object. The V530-R160 is factory set to start up in scene 0. In addition
to this, however, there are other scenes, scenes 1 to 9.
The command for changing scenes can be input from a host device via a parallel I/O or serial
interface.
1.
The
MON
(monitor) mode or
RUN
mode
screen will be displayed.
2.
Move the cursor to
Scn
and press the
ENT
Key.