INTRODUCTION
Controller Installation Site
Do NOT install the V530-R160 in locations subject to the following condi-
tions:
• Ambient temperatures outside of 0 to +50
°
C (32 to 122
°
F) range
• Rapid temperature fluctuations (likely to cause condensation)
• Relative humidities outside of the 35 to 85% range
• Presence of corrosive or flammable gases
• Presence of dust, salt, or iron particles
• Direct vibration or shock
• Direct sunlight
• Water, oil, or chemical fumes or spray
Mounting Orientation
To improve heat dissipation, install the controller in the following orientation only:
Do not install the controller in the orientations shown in the following diagram.