![background image](http://html1.mh-extra.com/html/omron/v530-r160e/v530-r160e_user-manual_741447135.webp)
133
V530-R160
Operation Manual
SECTION
5
Set
ting Rea
din
g Co
nditions
(Q
RCode
)
SECTION 5
Setting Reading Conditions
At the bottom left of the screen are displayed the length of the L shape, the number of pixels per cell
(the numerical value in parentheses), the angle, and the coordinates of the three points. Adjust the
field of vision so that there are at least 5 pixels per cell.
Refer to pages 46 to 48 (Sec.2).
What is a pixel?
Refer to page 283 (Sec.10).
What is a cell?
Refer to page 284 (Sec.10).
10.
Designate the bottom left and bottom right points in the same way.
The selections for the range of angle are displayed.
11.
Select the code inclination range and press
the
ENT
Key.
Code inclinations are specified in relation
to 0
°
,
90
°
,
180
°
,
or 270
°
.
Example: When the inclination is
±
15
0
+
-
-15
90
0
270
15
180
Direction of the code
The gray part is the part for which
the inclination designation is effective.