SECTION 8
Communication with the Host
The asterisk (*) indicates the default setting.
Set Items and their details
Item
Selection
Attach digit no.
OFF*
The number of digits of the reading data is not output.
ON
The number of digits of the reading data is output.
The number of digits is shown in bytes.
• A letter or a number is 1 digit.
Limit Data Function
OFF*
All of the reading data is output.
ON
The specified range of reading data is output.
Specify the data output range with
Start Point
and
End Point
.
Start Point
When
ON
is set for
Limit Data Function
, set the
Start Point
of the data to be out-
put. The start number is counted from the beginning of the reading data. The num-
ber of digits is not included.
(1 to 999; default setting: 1)
End Point
When
ON
is set for
Limit Data Function
, set the
End Point
of the data to be out-
put. The end number is counted from the beginning of the reading data. The num-
ber of digits is not included.
(1 to 999; default setting: 999)
Polling
OFF*
The reading data will be output to the host immediately after it is read.
ON
When the V530-R160 is connected with a 1:1 connection, use the polling
command to control the timing of reading data outputs. Reading data is
output when a polling command is input.
Number
of digits
Reading data
0 3 0 2 0 0 1 0 3 2 6 - A B C D E F G - 0 8 1 5
Limit Data Function
Start Point
Limit Data Function
End Point
Example:
Reading data
Start Point: [4]
End Point: [8]
0 3 0 2 0 0 1 0 3 2 6 - A B C D E F G - 0 8 1 5