Communication with the Host
Settings at the Programmable Controller
• Turn OFF DIP switch 5 of CQM1H.
• Set the communications conditions.
Set DM6645 to
1001
, DM6646 to
0904
, DM6648 to
1000
and DM6649 to
0D00
.
Refer to the operation manual for CQM1H for the ways to change the setting.
• Set the read command.
Set DM0100 to
4047
and DM0100 to
4C00
.
Settings at the Controller
Make the following communication settings.
Item
Setting
Communications method
Normal
Baud rate
9600 bps
Data length
7 bit
Parity bits
EVEN
Stop bits
2 bit
Header
None
Footer
CR
Item
Setting
Baud rate
The same settings as those of
the Programmable Controller.
Data length
Parity bits
Stop bits
Header
Footer
FCS
OFF
Mode