V530-R160
Operation Manual
SE
C
T
IO
N
8
Parallel I/O
SECTION 8
Communication with the Host
Continuous Reading (When Trigger Mode is [Continuous Reading])
Output signal
Output signal
Function
RUN
Turns ON during
RUN
mode.
BUSY
Shows that the V530-R160 is reading an image, changing settings, etc. Do not input the
next command while the BUSY signal is ON. Otherwise, the commands input during com-
mand execution or processing may not be properly executed.
OK/NG
Outputs the judgement under the set reading conditions. (Can be set to turn ON for either
OK or NG judgement.)
GATE
Used to control the timing with which the reading judgement is read at the host device.
The duration for which the GATE terminal is turned ON can be set as required for the host
device to correctly read the reading judgement.
Make the output cycle longer than the gate ON delay plus the gate ON time, but shorter
than the duration of the reading (TRIG A input). If the cycle is longer than the duration of
the reading, the input timing falls behind as readings are repeated. Gate ON delay, Gate
ON time and Output period are set under the set communications conditions.
Refer to page 192.
Input signal
Signal
Function
TRIG B
Performs continuous reading while the TRIG B terminal is ON.
Enter RUN mode.
Leave RUN mode.
RUN
BUSY
OFF
ON
OFF
ON
TRIG B
OFF
ON
Perform reading.
Perform reading.
Perform reading.
Judgement
Gate ON time
Gate ON delay
OK/NG
(RS-232C)
GATE
OFF
ON
Output period
Note: The output time to RS-232C changes depending on the data volume and
baud rate.
Note: A delay of 33.3 ms max. occurs before starting to read images
after the TRIG B signal is turned ON.