Setting Reading Conditions
Auto Pattern Select
If multiple patterns are registered, the controller references the patterns in sequence starting
from pattern 0, and checks them by comparison against the read code.
If ON is set for this function, the controller first references the pattern used immediately before,
then references the rest in order of diminishing frequency of use.
The order of priority of the patterns can be confirmed on the Pattern list screen.
When the first reading starts (when the pattern frequency of use is 0), the controller starts referenc-
ing from pattern 0.
When a registered pattern is deleted, the frequency of use of the relevant pattern is cleared.
Note also that if the controller power is switched OFF without saving the setting data, the pattern fre-
quency of use information is cleared. If the setting data has been saved, the frequency of use infor-
mation is retained.
Pattern frequency
of use
Referenced in the order Pattern 3 Pattern 1 Pattern 2 Pattern 0...
Pattern 0
Pattern 1
Pattern 2
Pattern 4
Referenced in the order Pattern 0 Pattern 1 Pattern 2...
Pattern 0
Pattern 1
Pattern 2
Pattern 3
Pattern 4
Auto pattern
select: OFF
Auto pattern
select: ON
Pattern 3
Pattern used
immediately before
for reading
(Priority 01) (Priority 02)
(Priority 03)
(Priority 01)
(Priority 02)
(Priority 03)
(Priority 04)
2 times
5 times
10 times
0 times