135
V530-R160
Operation Manual
SECTION
5
Set
ting Rea
din
g Co
nditions
(Q
RCode
)
SECTION 5
Setting Reading Conditions
If reading is performed successfully, the teaching function will automatically turn OFF. If reading is
not performed correctly (NG), the teaching function will stay ON. To turn the teaching function OFF,
go to the screen in
3.
(pattern list screen). To redo pattern registration, enter
SET
mode and start
the procedure again from
5.
.
The following setting information for pattern registration is displayed on the
Pattern list
screen.
To register a pattern again or register a new pattern, select the pattern number and press
ENT
Key,
and repeat the procedure from step
5.
.
Refer to page 131.
Item
Description
Pattern
Selected pattern number
Version
Matrix size (Version)
Color
Symbol color of the pattern
R&L rev.
Execution/non-execution of pattern Right & Left reverse
Corr. (Correlation)
Pattern correlation value
Priority
Pattern sequence used when reading
Refer to page 113.
Applied rate
Applied rate of the pattern
* The maximum number of reads is the most recent 10000.
Pattern setting information
Number of times a pattern is used
Total reads*
Applied rate
=