background image

AY-V64B 

Multi-Reader 

Installation and Programming Manual 

 

Summary of Contents for AY-V64B

Page 1: ...AY V64B Multi Reader Installation and Programming Manual ...

Page 2: ...al property rights covering the subject matter in this manual TEXTS IMAGES AND ILLUSTRATIONS INCLUDING THEIR ARRANGEMENT IN THIS DOCUMENT ARE SUBJECT TO THE PROTECTION OF COPYRIGHT LAWS AND OTHER LEGAL RIGHTS WORLDWIDE THEIR USE REPRODUCTION AND TRANSMITTAL TO THIRD PARTIES WITHOUT EXPRESS WRITTEN PERMISSION MAY RESULT IN LEGAL PROCEEDINGS The furnishing of this manual to any party does not give t...

Page 3: ...2 5 1 Transmit Mode 12 5 2 Programming the AY V64B 12 5 3 Entering Programming Mode 13 5 4 Exiting Programming Mode 14 5 5 Selecting Keypad Transmission Format 14 5 5 1 Keypad Transmission Format Option Number 15 5 6 Selecting Proximity Card Transmission Format 20 5 6 1 Proximity Card Transmission Format Option Number 20 5 7 Changing the Programming Code 21 5 8 Changing the Facility Code 22 5 9 Re...

Page 4: ...List of Figures iv AY V64B Installation and Programming Manual List of Figures Figure 1 Removing the Top Cover 9 ...

Page 5: ...List of Tables AY V64B Installation and Programming Manual v List of Tables Table 1 Wiring Colors 11 Table 2 Programming Menus 13 Table 3 Keypad Transmission Format 15 ...

Page 6: ...ure options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent noncompliance damage or injury The text images and graphics contained in th...

Page 7: ... to output eight different data formats The AY V64B utilizes flash firmware for easy upgrades 1 1 Box Content Before beginning verify that all of the following is in the box If anything is missing please report the discrepancy to your nearest Rosslare office The AY V64B package contains the following items One AY V64B access control unit Installation kit Installation and operating manual 1 2 Ancil...

Page 8: ...collector active low max sink current 30 mA Maximum Cable Distance to Controller 150 m 500 ft Card Read Distance 22 cm 9 in Environmental Characteristics Operating Temp Range 20 C to 63 C 4 F to 145 F Operating Humidity Range 0 to 95 non condensing Suitable for outdoor use meets IP54 Dimensions Height x Width x Depth 125 x 125 x 21 mm 4 9 x 4 9 x 0 8 in Weight 285 g 10 1 oz Measured using a Rossla...

Page 9: ...when mounting the reader 3 1 The Installation Kit The Installation kit comprises of the following items that are to be used during the installation procedure One installation template Two pan head screws and wall plugs One L shaped security screw tool Two security screws 3 2 Installing the AY V64B When installing the reader you must remove the snap off cover to access the screw holes Figure 1 Figu...

Page 10: ...d location 3 Using the template as a guide drill two holes the size of which are indicated in the template to install the reader onto the surface 4 Drill a 10 mm 7 16 hole for the cable In the event that you are installing the reader on metal place a grommet or electrical tape around the edge of the hole 5 Route the interface cable from the reader to the controller A linear type power supply is re...

Page 11: ...tput is being utilized connect the purple wire to the correct input on the controller Table 1 Wiring Colors Reader Color Function 5 16 VDC Red DC Input Shield Ground Black Ground Data 1 White Data 1 Data 0 Green Data 0 LEDCTL Brown LED Control Tamper Purple Tamper 4 Trim and cover all unused conductors The individual wires from the Reader are color coded according the Wiegand standard When using a...

Page 12: ...t keypad transmission formats see Section 5 5 Proximity cards presented to the reader are always sent in 26 Bit Wiegand Clock Data or Card PIN Wiegand format see Section 5 6 5 2 Programming the AY V64B Programming the AY V64B is done solely via the unit s keypad driven programming menu system To reach the programming menu system the reader must first be placed into Programming mode see Section 5 3...

Page 13: ...rity Bits Wiegand 26 Bit Single Key 3x4 Matrix Keypad 1 to 8 Keys BCD Clock Data Single Key 1 Selecting Proximity Card Transmission Format Wiegand 26 Bit Clock Data Wiegand Card PIN 2 Changing the Programming Code 3 Changing the Facility Code 4 Return to Factory Default Settings 0 5 3 Entering Programming Mode To enter Programming mode 1 Press the key 4 times The Transmit LED turns off and the Pro...

Page 14: ...Wrong entries may reset the reader back to Transmit mode While in Programming mode if no key is pressed for 30 seconds the AY V64B exits Programming mode and returns to Transmit mode 5 5 Selecting Keypad Transmission Format The AY V64B has eight different keypad transmission selectable formats To select a keypad transmission format 1 Enter Programming mode Press 1 to enter Menu 1 2 The Transmit LE...

Page 15: ...r the keypad transmission format you wish to select Table 3 Keypad Transmission Format Keypad Transmission Format Option Number Single Key Wiegand 6 Bit Rosslare Format Single Key Wiegand 6 Bit with Nibble Parity Bits Single Key Wiegand 8 Bit Nibbles Complemented 4 Keys Binary Facility code Wiegand 26 Bit 1 to 5 Keys Facility code Wiegand 26 Bit 6 Keys BCD and Parity Bits Wiegand 26 Bit Single Key...

Page 16: ...ented This option inverts the most significant bits in the message leaving the least 4 significant bits as Binary Coded Decimal BCD representation of the key The host system receives an 8 bit message 0 11110000 6 10010110 1 11100001 7 10000111 2 11010010 8 01111000 3 11000011 9 01101001 4 10110100 01011010 A in Hexadecimal 5 10100101 01001011 B in Hexadecimal 5 5 1 4 4 Keys Binary Facility Code 26...

Page 17: ...rs up to 5 keys and outputs keypad data with a facility code like a 26 Bit card output The facility code is set in Programming Menu number four and can be in the range 000 to 255 The factory default setting for the facility code is 000 see Section 5 8 The keypad PIN code can be one to five digits long and can range between 0 and 65 535 When entering a keypad PIN code that is less than 5 digits lon...

Page 18: ...cross the Wiegand Data lines as a BCD message If the entry of the 6 digit keypad PIN code is disrupted and no number key is pressed within 5 seconds the keypad clears the PIN code entry buffer generates a medium length beep and is ready to receive a new 6 digit keypad PIN code EP AAAA BBBB CCCC DDDD EEEE FFFF OP Where A First key entered D Fourth key entered B Second key entered E Fifth key entere...

Page 19: ... 5 5 1 8 1 to 8 Keys BCD Clock Data Buffers up to 8 keys and outputs keypad data without a facility code like standard Clock and Data card output The keypad PIN code can be one to eight digits long The PIN code length is selected while programming the reader for Option 8 The reader transmits the data when it receives the last key press of the PIN code The data is sent across the two data output li...

Page 20: ... the appropriate option number for the proximity card transmission format that you wish to select see Section 5 6 1 Three beeps are emitted on success The system returns to Transmit mode The Program LED turns off and the Transmit LED turns red If an incorrect option number is entered the reader returns to Transmit mode and the keypad transmission format remains unchanged 5 6 1 20BProximity Card Tr...

Page 21: ... that reader is waiting for the PIN code The entered pin code buffered up to 5 keys and outputs keypad data with a facility code much like option 5 above 5 7 Changing the Programming Code To change the Programming code 1 Enter Programming mode 2 Press 3 to enter Menu 3 The Transmit LED turns red 3 Enter the new 4 digit code you wish to set as the Programming code The system returns to Transmit mod...

Page 22: ...urns red Facility codes can be in the range between 000 and 255 5 9 17BReturn to Factory Default Settings You must be very careful before using this command Doing so erases the entire memory which includes all user and special codes In addition all codes are returned to their factory default settings To return to factory default settings 1 Enter Programming mode 2 Press 0 to enter Menu 0 The Trans...

Page 23: ...to Normal mode without erasing the memory of the controller 5 10 Replacing a lost Programming Code In the event that the Programming code is forgotten the AY V64B may be reprogrammed in the field using the following instructions 1 Remove power from the reader 2 Activate tamper by removing the reader from the wall or removing the reader s case 3 Apply power to the reader 4 You now have 10 seconds t...

Page 24: ... A Limited Warranty The full ROSSLARE Limited Warranty Statement is available in the Quick Links section on the ROSSLARE website at www rosslaresecurity com Rosslare considers any use of this product as agreement to the Warranty Terms even if you do not review them ...

Page 25: ...rosslaresecurity com Europe Rosslare Israel Ltd Rosh HaAyin Israel Tel 972 3 938 6838 Fax 972 3 938 6830 support eu rosslaresecurity com Latin America Rosslare Latin America Buenos Aires Argentina Tel 54 11 4001 3104 support la rosslaresecurity com China Rosslare Electronics Shenzhen Ltd Shenzhen China Tel 86 755 8610 6842 Fax 86 755 8610 6101 support cn rosslaresecurity com India Rosslare Electro...

Reviews: